Citation : Ronald Kefurt, Felix B. Langer, Karin Schindler, Soheila Shakeri-Leidenmühler, Bernhard Ludvik, Gerhard Prager, 2015, 'Hypoglycemia after Roux-En-Y gastric bypass: detection rates of continuous glucose monitoring (CGM) versus mixed meal test', Surgery for Obesity and Related Diseases, vol. 11, no. 3, pp. 564-569
Link to Scientific Article :
Hypoglycemia after Roux-En-Y gastric bypass: detection rates of continuous glucose monitoring (CGM) versus mixed meal test
Date of Publication: 2015
Study Summary
This study used continuous glucose monitoring (CGM), a small sensor worn for five days, to look for low blood sugar in 40 patients an average of about seven years after gastric bypass. CGM detected episodes of hypoglycemia (blood sugar below 55 mg/dL) in 75% of patients, compared with only 29% found by a standard mixed-meal test. Thirty-eight percent of patients had low blood sugar during the night, and patients averaged three episodes lasting a little over an hour each. The authors conclude that hypoglycemia after gastric bypass is more common than expected, and that CGM may help with screening and with evaluating diet, medication or surgical treatment.
Related: Dumping Syndrome and Hypoglycemia